← All courses

309A + 442A Electrician Exam Prep Bundle cover — both complete courses

Bundle · Ontario / Red Seal

309A + 442A Electrician Exam Prep Bundle — Both Complete Courses

Going for the dual ticket? Plants across Ontario post “442A or 309A” — holding both makes you the candidate who qualifies either way. This bundle includes both complete courses: the full 309A Electrician Exam Prep course and the full 442A Industrial Electrician Exam Prep course, with every PDF, every narrated video lesson, and both 100-question mock exams. Bought separately the two courses are CA$398; the bundle is CA$299.

Who it’s for: Electricians writing both exams — 309A holders adding the industrial ticket, 442A holders adding construction, and apprentices planning the dual-ticket route from the start.

  • 2 complete courses — 309A and 442A
  • 193 pages of PDF study guides
  • 19 narrated video lessons
  • Two 100-question mock exams

Includes the complete 309A and 442A courses exactly as sold individually — no abridged versions. Independent prep courses — not affiliated with Skilled Trades Ontario, the Red Seal Program, or CSA.

Try it first

Free Practice Questions

Five questions from the 309A course and five from the 442A course — taken straight from the practice sets inside each course. The full courses carry 190 and 205 practice questions respectively, each with a full timed 100-question mock exam.

1. How many questions are on the 309A Red Seal exam, and what is the pass mark? (309A course)

  • A. 125 questions; 65%
  • B. 100 questions; 70%
  • C. 100 questions; 75%
  • D. 150 questions; 70%

Answer: B. 100 multiple-choice questions, 70% (70 correct) to pass, four hours to write.

2. Which table gives the minimum size of a bonding conductor for a service? (309A course)

  • A. Table 13
  • B. Table 14
  • C. Table 16
  • D. Table 45

Answer: C. Table 16 sizes grounding and bonding conductors based on the size (ampacity) of the largest ungrounded conductor. You'll use it in Block B questions constantly.

3. A circuit supplies a continuous load of 64 A. What is the minimum rating of overcurrent protection (not a 100%-rated assembly)? (309A course)

  • A. 64 A
  • B. 70 A
  • C. 80 A
  • D. 100 A

Answer: C. Continuous loads are limited to 80% of the circuit rating: 64 ÷ 0.80 = 80 A (equivalently, 64 × 1.25). Rule 8-104 method.

4. A 240 V single-phase run, 45 m one-way, carries 24 A on No. 8 AWG copper (resistance ≈ 2.06 Ω/km). The voltage drop is approximately: (309A course)

  • A. 2.2 V (0.9%)
  • B. 4.4 V (1.9%)
  • C. 8.9 V (3.7%)
  • D. 17.8 V (7.4%)

Answer: B. VD = 2 × 45 × 24 × 2.06 ÷ 1000 = 4.45 V; 4.45 ÷ 240 = 1.85%. Within the 3% branch-circuit limit. Option C is the answer if you mistakenly double-count the length; option D if you also drop the ÷1000 discipline.

5. A 45 kVA three-phase transformer has a 600 V primary. Its rated primary current is approximately: (309A course)

  • A. 25 A
  • B. 43.3 A
  • C. 75 A
  • D. 130 A

Answer: B. 45,000 ÷ (1.732 × 600) = 43.3 A. Option C is the single-phase answer (45,000 ÷ 600) — the √3 trap again.

6. Which three blocks together account for 61 of the 100 questions? (442A course)

  • A. Blocks A, B and C
  • B. Blocks B, C and D
  • C. Blocks B, D and F
  • D. Blocks D, E and F

Answer: C. Generating/distribution/service systems (23) plus rotating equipment and control systems (21) plus process control systems (17) = 61. This is why this course weights your study time toward distribution, motors and drives, and process control.

7. Which section covers motors and generators? (442A course)

  • A. Section 26
  • B. Section 28
  • C. Section 36
  • D. Section 62

Answer: B. Section 28 — Motors and generators. It works with Table 45 (full-load currents), Table 29 (short-circuit/ground-fault protection percentages), and Table 44 (locked-rotor kVA by code letter).

8. A 30 hp, 575 V, three-phase motor has a Table 45 full-load current of 32 A. What minimum conductor ampacity does the Code require for its branch circuit? (442A course)

  • A. 32 A
  • B. 36.8 A
  • C. 40 A
  • D. 56 A

Answer: C. Rule 28-106: 125% of FLC for a single motor → 32 × 1.25 = 40 A. Option D is the Table 29 fuse-percentage trap (175%) applied to the wrong step.

9. During a lockout, how is zero energy verified at the work point? (442A course)

  • A. The disconnect handle is in the OFF position
  • B. Test with a meter proved on a known live source before and after testing the work point (live–dead–live)
  • C. The equipment does not start when the start button is pressed
  • D. A tag is applied to the disconnect

Answer: B. Handles lie (welded contacts, wrong disconnect, backfeeds). The live–dead–live method proves both the absence of voltage and that your meter was working when it said so.

10. A current transformer (CT) secondary must never be opened while the primary is carrying load because: (442A course)

  • A. The meter would read zero
  • B. The open secondary can develop dangerously high voltage and overheat the core
  • C. The primary current would double
  • D. It would blow the primary fuse

Answer: B. A CT is a step-up transformer into an open circuit: dangerously high secondary voltage, insulation failure, and a shock/burn hazard. Short the secondary before removing the meter — a standard exam and field rule.